Back to Engineering Blog
Engineering Field Notes 3 min read

Voice Assistant Dropouts, and Tuning for the Far Side of the Bed

A voice unit dropped off the network eighteen times in fourteen hours. Pings showed real outages, not a stale connection, and firmware was ruled out. We also tuned wake-word sensitivity for a bedroom, within the narrow set of controls the firmware exposes.

Jason NevillBy , Houston, TX
#HomeAssistant#Voice#WiFi#ESPHome

Key Architectural Takeaways

  • Correlate the application's 'unavailable' windows with ping logs to tell a real network outage from a stale connection.
  • A second, newer unit dropping the same way rules out a bad unit and firmware at once.
  • Know the tuning surface: this firmware exposes sensitivity and end-of-speech presets, not seconds or mic gain.

The symptom

One voice unit flapped between unavailable and idle 18 times in 14 hours. The rest of Home Assistant and every other entity stayed stable.

Separating a real outage from a stale connection

We ran ping loggers against the units from a separate host. The outages lasted between 13 and 95 seconds and lined up exactly with the windows when Home Assistant reported the unit unavailable. So these were genuine network losses, not a stale ESPHome connection. Baseline latency was also poor for a LAN: averages of 57 to 91 ms with spikes above 200 ms.

What we ruled out

  • Firmware. The old unit went from 26.6.0 to 26.9.0 with no change.
  • A bad unit. A second, new unit arrived on 26.9.0 and dropped as well.
  • The hypervisor NIC bug. The overnight drops began before the NIC hang we fixed the same day, so it was unlikely to be the cause.

That leaves the shared path: the power adapter (the old unit's had been swapped), the 2.4 GHz channel or band steering on the access point, and Wi-Fi power save. These remain suspects. We logged the data for a six-hour comparison and did not claim a root cause we had not proven.

Tuning the bedroom unit

The complaint was that it did not hear commands from the far side of the bed and stopped listening too soon. We changed two controls live:

  • Wake-word sensitivity: "Slightly sensitive" to "Very sensitive".
  • Finished-speaking detection: "default" to "relaxed".

We read the states back to verify. The limits are worth recording: the firmware offers only default, relaxed and aggressive for end-of-speech (no seconds value) and has no mic-gain control, and "very sensitive" may raise false wakes from TV audio. Other levers are placement, a second wake-word slot, or another unit on the far nightstand. The original values are recorded as the revert.

A new unit, a new room

The second unit was set up in an area for the desk with its own wake word and the "full local assistant" pipeline. No entities were assigned to that area yet, so area-relative commands like "turn off the light" would not resolve there until some are.

Takeaway

Measure before you theorise. Packet-level evidence showed where the problem was, ruled out the expensive guesses, and left an honest short list of what is still unknown.

Follow the build on LinkedIn or by RSS.

All Articles

Follow the build

Questions about the build, or spotted something we got wrong? Find us on LinkedIn and GitHub.