'Turn On the Living Room TV': The Voice Assistant Said Done and Nothing Happened
A Voice Preview Edition answered 'turned on the media player' and the TV stayed off. The assistant was resolving the command to the wrong entity, one that cannot wake an LG from standby over Wi-Fi. Aliases and a smaller exposure list fixed it.

Key Architectural Takeaways
- Read the assistant's pipeline debug output before blaming speech recognition; here the transcript was correct and the entity choice was wrong.
- Expose only the entities that can actually do the job, and add spoken aliases to the ones that can.
- Several integrations for one TV mean several entities with the same name; fewer exposed entities means fewer wrong answers.
The symptom
From the desk Voice Preview Edition: "turn on the living room TV." The reply was "turned on the media player," and the TV stayed dark. In the bedroom, the unit played two tones and did nothing.
What the pipeline showed
Home Assistant's assist_pipeline/pipeline_debug output showed the transcription was accurate and the intent parsed correctly. The failure was in entity resolution. Each room had three or four TV-like media players: the streaming box, a Cast entity, the LG's webOS integration, and in one room a duplicate LG entity from the HomeKit controller. The assistant had picked the webOS and HomeKit LG entities.
Those entities cannot power an LG on from standby over Wi-Fi. What does wake the TV is the Google TV streaming box, because it sends HDMI-CEC.
The fix
Live, in the entity registry:
- Aliases on the box media players ("Living Room TV", "Living Room Television", "Master Bedroom TV", "Bedroom TV") so the natural phrases resolve to them.
- Removed from voice exposure: both webOS LGs, the duplicate HomeKit LG, and two extra Google TV entities.
- A snapshot of the exposure list taken before the change, kept as the revert path.
Verification
We tested with the text conversation endpoint in both rooms: off and on each resolved to the box, and the LG followed, about 12 seconds in the bedroom. In the living room the TV entity took about 53 seconds to report "on" after a full off. The owner then confirmed by real voice that the commands work from both units.
Known limits
The speech-to-text model occasionally mishears a phrase. A compound command ("turn on X and Y") is untested. Lights, fans and lamps are next, using the same alias and exposure approach. A later audit of the exposure list found 38 exposed entities with five duplicate spoken names, so the same cleanup applies there.
Takeaway
When a voice assistant confirms and nothing happens, the bug is almost never the microphone. Look at which entity it chose, then shrink the list of things it is allowed to choose from.